Nortel DMS-100 Series Maintenance Manual page 313

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an ESA critical, minor alarm
At the MAP terminal
1
An alarm can be audible. To silence the alarm type
>MAPCI;MTC;SIL
and press the Enter key.
2
To access the PM level of the MAP display, type
>PM
and press the Enter key.
3
To identify the central-side busy (CBsy) ESA processor, type
>DISP STATE CBSY ESA
and press the Enter key.
If ESA
is CBsy
is not CBsy
4
To post the ESA processor, type
>POST ESA esa_no
and press the Enter key.
where
esa_no
is the number of the ESA processor (0 to 255)
Example of a MAP response:
REM1
ESA
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-129
0 CBsy
critical, minor
(continued)
Do
step 4
step 11
ESA