Advertisement

4
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
Example of a MAP response :
Node inservice troubles exist:
One or both Units inservice trouble
LCM
UNIT 0
LCM
UNIT 1
Ringing Generator Failure:Ring Generator in Excess load
If the system
indicates RG failure
does not indicate RG failure
At the LCM
5
Inspect the ringing generator. Check to see if the light-emitting diode (LED) is
ON.
If the LED
is ON
is OFF
6
Move the power switch to the ON position to power up the ringing generator.
The LED should go OFF. These switches are identified as
RG 0
RG 1.
If the system
restores power
does not restore power
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-115
No Inservice trouble Exist:
Inservice Troubles Exist:
PM LCM RG
minor
(continued)
Do
step 7
step 5
Do
step 6
step 7
Do
step 16
step 7