Nortel DMS-100 Series Maintenance Manual page 291

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

24
To RTS the two line subgroups, type
>RTS DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups that associate with the
drawer that has defects
Example of a MAP response:
OSvce Tests Initiated
LCM
REM1 00 0
LCM
REM1 00 0
Repeat this step for the other line subgroup that associates with the drawer that
has defects.
If return to service
passes
fails
25
To busy the LCM unit that associates with the alarm, type
>BSY UNIT Icm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit you must busy (0 or 1)
RLCM alarm clearing procedures 7-107
Drwr 2 Tst Passed
Drwr 2 Rts Passed
DMS-100 Family RLCM Maintenance Manual XPM12 and up
minor
(continued)
Do
step 31
step 29
RLCM