16
To test the new RG, type
>TST UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1) associated with the new RG
If TST
passes
fails
17
To align RG activity to the preferred RG, if required, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
Example of a MAP response.
LCM REM2 00 0 InSv Links
Unit 0: InSv
Unit 1: InSv
Drwr:
01
23
45
..
..
..
Note: Repeat this step to assign both units of the LCM to the preferred RG.
If SWRG command
passes
fails
18
Go to the card replacement procedure for the NT6X30 circuit card in Card
Replacement Procedures . Complete the procedure and go to step 13 of this
procedure.
19
For additional help, contact the next level of support.
20
The procedure is complete. If the system displays other alarms, refer to the
correct alarm clearing procedures for the indicated alarms.
RLCM alarm clearing procedures 7-119
OOS: Cside 0 Pside 0
/RG:0
/RG:0
11
11
11
67
89
01
23
45
..
..
..
..
..
DMS-100 Family RLCM Maintenance Manual XPM12 and up
PM LCM RG
PM LCM RG
minor
minor
Do
step 17
step 19
11
11
RG: Pref 0 InSv
67
89
Stby 1 InSv
..
..
Do
step 20
step 19
(continued)
(end)