Nortel DMS-100 Series Maintenance Manual page 238

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-54 RLCM alarm clearing procedures
RLCM RG
major
(continued)
Summary of clearing anRLCM RG major alarm (continued)
Power up ringing
generator
1
Switch RG
activity to the
2
good RG
BSY associated
LCM unit
TST LCM unit
TST passed?
Replace faulty
3
RG
4
297–8351–550 Standard 04.01 August 1999
Y
RTS LCM unit
N
RTS passed?
Contact next
level of support
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Align units to
Y
preferred RG
N
End of
procedure