Nortel DMS-100 Series Maintenance Manual page 302

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-118 RLCM alarm clearing procedures
PM LCM RG
minor
(continued)
13
14
15
297–8351–550 Standard 04.01 August 1999
To return the LCM unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LCM unit manually busied in step 9
If RTS
passes
fails
To align RG activity to the new RG, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
Example of a MAP display:
LCM REM2 00 0 Unit 1 SWRG Passed
If the SWRG command
passes and RG activity must be
switched for the other unit
passes, and RG activity is
acceptable for both units
fails
Repeat step 14 for the other LCM unit in this frame.
Do
step 14
step 19
Do
step 15
step 16
step 19

Advertisement

Table of Contents
loading