8-114 Card replacement procedures
NT6X27
in HIE
(continued)
17
18
19
20
21
22
297–8351–550 Standard 04.01 August 1999
Determine if there are links to clear.
If there
are links to clear
are no links to clear
Return to the procedure that directed you to this procedure. Continue as
directed.
To post the ILCM, type:
>POST ILCM site frame lcm_no
and press the Enter key.
where
site
is the site name of the PRLCM (alphanumeric)
frame
is the frame number of the PRLCM cabinet
lcm_no
is the number of the ILCM
To return the busy unit to service, type:
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the ILCM unit busied in step 10
If RTS
fails
passes
Send defective cards for repair according to local procedure.
Record the following items in office records:
date of card replacement
serial number of the card
problems that prompted replacement of the card.
Proceed to step 24.
Do
step 12
step18
Do
step 23
step 21