7-92 RLCM alarm clearing procedures
RMM
major
(continued)
22
23
24
25
297–8351–550 Standard 04.01 August 1999
To leave the disk utility, type
>QUIT
and press the Enter key.
To reload the RMM, type
>LOADPM
and press the Enter key.
If
load fails
load passes
To identify the RLCM with links in a SysB condition, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
LINK 0: LCM REM1 00 0
LINK 1: LCM REM1 00 0
To post the RLCM identified in step 24, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0 to 511)
lcm
is the number of the LCM
Do
step 35
step 31
0;CAP MS;STATUS:SysB,;MSGCOND:CLS
1;CAP MS;STATUS:SysB,;MSGCOND:CLS