Nortel DMS-100 Series Maintenance Manual page 481

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Determine the correct FSP switch for the shelf in which the power converter
was replaced from the diagram below. The switches are numbered
corresponding to the shelf position.
Circuit breaker
CB6
CB7
Note: For the NTNX14AA cabinet the circuit breaker assignments are:
Circuit breaker
CB2
CB7
c.
Turn the circuit breaker on for the unit with the new power converter.
a. The converter fail LED will be extinguished.
b. The frame fail lamp on the FSP will be extinguished.
8
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 9.
At the MAP display
9
Load the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit (0 or 1)to be loaded
If
message "loadfile not found in
directory" is received
load passed
load failed
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-163
Unit FED
LCA 0
LCA 1
Unit FED
LCA 0
LCA 1
Do
step 10
step 29
step 33
NT6X53
RLCM
(continued)
Locations
Shelf 04 slot 01
Shelf 21 slot 01
Locations
bay 0 slot 01
bay 0 slot 01