Nortel DMS-100 Series Maintenance Manual page 286

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-102 RLCM alarm clearing procedures
RLCM
minor
(continued)
11
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
12
13
297–8351–550 Standard 04.01 August 1999
To identify the defective P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Record information for links that have a state other than OK.
To choose and busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a peripheral-side (P-side) link that has defects
from step 11
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that has defects busied in step 12
If test
passes
fails
2;Cap MS;Status: OK
1;Cap MS;Status: SysB,;MsgCond: CLS
Do
step 14
step 21
;MsgCond: OPN