8-126 Card replacement procedures
NT6X45
HIE
(continued)
23
24
25
26
27
28
297–8351–550 Standard 04.01 August 1999
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 20
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the ESA processor by typing
>LOADPM
and pressing the Enter key.
If loadpm
passed
failed
Return the ESA processor to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 30.
Do
step 26
step 29
Do
step 27
step 29