Nortel DMS-100 Series Maintenance Manual page 285

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RLCM site
6
Inspect the ringing generator to check if the light-emitting diode (LED) is lit.
If the LED
is lit
is not lit
7
To power up the ringing generator, move the power switch to the ON position.
(The LED light must go off.) The switches are:
RG 0 which corresponds to LCM unit 0 CB2
RG 1 which corresponds to LCM unit 1 CB4
8
Determine if power is restored to the ringing generator.
If power
is restored
is not restored
At the MAP terminal
9
To identify C-side links to the host PM, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
10
To post the host peripheral, either a line group controller (LGC), a lline trunk
controller (LTC) or a remote cluster controller (RCC), type
>POST pm_type pm_no
and press the Enter key.
where
pm_type is LGC, LTC, or RCC
pm_no
is the number of the host peripheral
RLCM alarm clearing procedures 7-101
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
DMS-100 Family RLCM Maintenance Manual XPM12 and up
minor
(continued)
Do
step 7
step 25
Do
step 31
step 25
;MsgCond: OPN
;MsgCond: CLS
RLCM