7-62
7-62
RLCM alarm clearing procedures
Ext FSP
RLCE frame major
Alarm display
CM
.
Indication
At the MTC level of the MAP, the alarm code FSP, preceded by a number,
appears under the EXT header of the alarm banner. This code indicates an
external frame supervisory panel (FSP) alarm.
The letter M below the alarm code indicates the alarm class is major. The
number under the EXT header of the alarm banner indicates the number of
frames affected by the problems.
Meaning
One or more frames in the office has a power problem fault or a cooling unit
fault.
Impact
The type of fault and the type of frame that contains the fault determines the
fault's effect on subscriber service.
Common procedures
There are no common procedures.
Action
The section provides a summary flowchart of the procedure and a list of
steps to clear the alarm. A detailed step-action procedure follows the
flowchart.