Nortel DMS-100 Series Maintenance Manual page 506

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-188 Card replacement procedures
NT6X71
RLCM
(continued)
Replacing an NT6X71 card in an RLCM
At your current location
1
At the MAP terminal
2
3
4
5
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the line test position (LTP) level of the MAP display and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and pressing the Enter key.
where
site is the name of the site where the RLCM is located
lcm is the number of the RLCM with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP display:
LCC PTY RNG .....LEN..........
1FR
REM1 00 0 03 03
Check the status of the posted line.
If the line status is
ManB
not ManB
Busy the line by typing
>BSY
and pressing the Enter key.
Go to the procedure "Replacing a line card". When you have completed the
procedure, return here.
DN
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4

Advertisement