Powering Down Sms - Nortel DMS-100 Series Maintenance Manual

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

11-10 Advanced troubleshooting procedures
4 List the PM LOADS at the input-output device. List the specified PM
5
6
7
8 Perform a cold SWACT.
9 Use the NEXT command to post the next SMS to return to service until

Powering down SMS

The SMS is part of the host office. The SMS uses the general host office
power-down procedure to power down. Complete the following steps to
power down the SMS alone.
1 Enter the PM level at the MAP terminal.
2
3
4
5 Make the unit inactive and power the unit down. In step 2, post the SMS
297-8231-550 Standard 09.01 August 1998
a. Repeat steps 2 and 3 for the other SMS unit.
b. Busy both SMS units.
LOADS in use to RTS the units. Normally, you complete this step
during the power-up procedure.
>DSKUT;LISTVOL volume name ALL
where
volume name is the volume on which the PMLOADS are found
For example:
>DSKUT;LISTVOL DOOOXPM ALL
Note: List the PMLOADS once.
>LOADPM UNIT unit no CC
>TST UNIT unit no
>RTS UNIT unit no
you restore all the SMSs.
Note: The SLC-96 is an AT&T product. Refer to AT&T documentation
for SLC-96 power-up procedures.
>POST SMS
>BSY PM
>TRNSL C
unit. Busy one or more C-side links. Busy the same SMS unit.

Advertisement

Table of Contents
loading

Table of Contents