Nortel DMS-100 Series Maintenance Manual page 230

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-46 RLCM alarm clearing procedures
RLCM
major
(continued)
Clearing an RLCM major alarm
At the MAP terminal
1
2
3
4
5
297–8351–550 Standard 04.01 August 1999
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type
>PM
and press the Enter key.
To identify the RLCM that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
To post the RLCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0 to 511)
lcm
is the number of the RLCM
Determine the fault indicators, type
>QUERYPM FLT
and press the Enter key.
If fault indicated
is ringing generator
is CBsy (C-side busy)
is SysB
is ManB
Do
step 6
step 9
step 13
step 17

Advertisement

Table of Contents
loading

Table of Contents