Nortel DMS-100 Series Maintenance Manual page 386

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-68 Card replacement procedures
NT2X70
HIE
(continued)
35
At the MAP display
36
37
38
297–8351–550 Standard 04.01 August 1999
Return the LCM unit to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Post the remote line concentrating module (RLCM) associated with the faulty
NT2X70 card by typing
>POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the RLCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
Busy unit 1 of the RLCM by typing
>BSY UNIT 1
and pressing the Enter key.
Post the ESA processor identified in step 4 by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor associated with the faulty
NT2X70 card.
Do
step 69
step 73