Replacing an NT6X74 card in an RMM
At your current location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
2
If you were directed to this procedure from another maintenance procedure, go
to step 8; otherwise, continue with step 3.
At the MAP display
3
Access the TTP level of the MAP and post the RMM that contains the card to
be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
4
Check the status of the RMM.
If RMM status is
MB, PMB, RMB
other
5
Busy the trunks that are associated with the card to be replaced by typing
>BSY ALL
and pressing the Enter key.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-197
OTDA00
BUSY Q
COM LANG
OTWAON23DA00 2001
Do
step 8
step 5
NT6X74
RMM
(continued)
DIG
STA S R DOT TE R
LO
P_IDL