8-142 Card replacement procedures
NT6X50
NT6X50
HIE
HIE
(end)
(continued)
20
21
22
23
24
25
297–8351–550 Standard 04.01 August 1999
Post the LCM by typing
>POST LCM site frame lcm_no
and pressing the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCE (0 to 511)
lcm_no
is the number of the LCM
Return the busied unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the RLCM unit busied in step 10
If RTS
failed
passed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Proceed to step 25.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue as
directed.
Do
step 24
step 22