Advertisement

8-118 Card replacement procedures
NT6X36
RLCE
(continued)
Replacing an NT6X36 card in an RLCE
At your current location
1
At the RLCE frame
2
3
297–8351–550 Standard 04.01 August 1999
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist-strap
grounding point of a frame supervisory panel (FSP) or
a modular supervisory panel (MSP) while handling
circuit cards. This protects the cards against damage
caused by static electricity.
Obtain a replacement card. Ensure that the replacement card has the same
product engineering code (PEC), including suffix, as the card being removed.
DANGER
Risk of electrocution
Some of the terminals inside the frame supervisory
panel (FSP) have an electrical potential of -48V
dc. Remove all jewelry before replacing a card in the
FSP. Do not touch any terminal in the FSP.
Unscrew the slotted nut on the left-hand side of the FSP.
Open the FSP panel.