8-176 Card replacement procedures
NT6X54
RLCM
(continued)
20
At the MAP terminal
21
22
23
24
297–8351–550 Standard 04.01 August 1999
If you were directed to this procedure from the Alarm clearing procedure ,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 21.
Determine which procedure to use to return the line subgroups to service.
If the card you are replacing is
NT6X54AA
NT6X54DA
Return the line subgroups to service by typing
>RTS DRWR lsg
and pressing the Enter key.
where
lsg
is one of two line subgroups (0 through 19) associated with the drawer
Note: Repeat this step for the other line subgroup associated with the line
drawer.
If RTS
passed
failed
Return the line subgroups to service by typing
>RTS DRWR
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.