Central management with Digi Remote Manager
7. (Optional) Set the amount of time that the TX54 device should wait between sending keep-
alive messages to the Digi Remote Manager when using a cellular interface. Allowed values are
from 30 seconds to two hours. The default is 290 seconds.
(config)> cloud drm cellular_keep_alive value
(config)>
where value is any number of hours, minutes, or seconds, and takes the format number{h|m|s}.
For example, to set the cellular keep-alive interval to ten minutes, enter either 10m or 600s:
(config)> cloud drm cellular_keep_alive 600s
(config)>
8. Set the number of allowed keep-alive misses. Allowed values are any integer between 2 and
64. The default is 3.
(config)> cloud drm keep_alive_misses integer
(config)>
9. (Optional) Configure the TX54 device to communicate with Digi Remote Manager by using SMS:
a. Enable SMS messaging:
(config)> cloud drm sms enable true
(config)>
b. Set the phone number for Digi Remote Manager:
(config)> cloud drm sms destination drm_phone_number
(config)>
c. (Optional) Set the service identifier:
(config)> cloud drm sms sercice_id id
(config)>
10. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
11. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Collect device health data and set the sample interval

You can enable or disable the collection of device health data to upload to Digi Remote Manager, and
configure the interval between health sample uploads. By default, device health data upload is
enabled, and the health sample interval is set to 60 minutes.
To disable the collection of device health data or enable it if it has been disabled, or to change the