Collect device health data and set the sample interval

You can enable or disable the collection of device health data to upload to Digi Remote Manager, and
configure the interval between health sample uploads. By default, device health data upload is
enabled, and the health sample interval is set to 60 minutes.
To avoid a situation where several devices are uploading health metrics information to Remote
Manager at the same time, the IX14 device includes a preconfigured randomization of two minutes for
uploading metrics. For example, if Health sample interval is set to five minutes, the metrics will be
uploaded to Remote Manager at a random time between five and seven minutes.
To disable the collection of device health data or enable it if it has been disabled, or to change the
health sample interval:
  WebUI
1. Log into the IX14 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click Monitoring > Device Health.