Collect Device Health Data And Set The Sample Interval - Digi TX54 User Manual

Hide thumbs Also See for TX54:
Table of Contents

Advertisement

Central management
15. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Collect device health data and set the sample interval

You can enable or disable the collection of device health data to upload to Digi Remote Manager, and
configure the interval between health sample uploads. By default, device health data upload is
enabled, and the health sample interval is set to 60 minutes.
To avoid a situation where several devices are uploading health metrics information to Remote
Manager at the same time, the TX54 device includes a preconfigured randomization of two minutes
for uploading metrics. For example, if Health sample interval is set to five minutes, the metrics will
be uploaded to Remote Manager at a random time between five and seven minutes.
To disable the collection of device health data or enable it if it has been disabled, or to change the
health sample interval:
  WebUI
1. Log into the TX54 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click Monitoring > Device Health.
4. (Optional) Click to expand Data point tuning.
Data point tuning options allow to you configure what data are uploaded to the Digi Remote
Manager. All options are enabled by default.
TX54 User Guide
Collect device health data and set the sample interval
899