System administration

Reset the device to factory defaults

Resetting the device to factory defaults performs the following actions:
Clears all configuration settings. When the device restarts, it uses the default configuration.
n
Deletes all user files including Python scripts.
n
Erases all automatically generated keys.
n
Clears event and system log files.
n
You can reset the device in the WebUI, at the command line, or by using the Reset button on the
device. You can also reset the device to the default configuration without removing scripts, keys, and
logfiles by using the revert command.
  WebUI
1. Log into the TX54 WebUI as a user with Admin access.
2. On the main menu, click System. Under Configuration, click Configuration Maintenance.
The Configuration Maintenance windows is displayed.
3. In the Erase configuration section, click ERASE.
4. Click CONFIRM.
5. After resetting the device:
a. Connect to the TX54 by using the serial port or by using an Ethernet cable to connect the
TX54 LAN1 port to your PC.
b. Log into the TX54:
User name: Use the default user name: admin.
Password: Use the unique password printed on the bottom label of the device (or the
printed label included in the package).