System administration
1. Log into the TX54 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click System > Power > Ignition sense control.
4. For Ignition power on delay, type the amount of time to wait to power on the device, after
the device detects that there is power on the ignition sensor.
Allowed values are any number of hours, minutes, or seconds, and take the format number
{h|m|s}.
For example, to set Ignition power on delay to ten minutes, enter 10m or 600s.
The default is 0s, meaning that there is no power on delay.
5. For Ignition power off delay, type the amount of time to wait to power off the device, after
the device detects that there is no longer power on the ignition sensor.
Allowed values are any number of hours, minutes, or seconds, and take the format number
{h|m|s}.
For example, to set Ignition power off delay to ten minutes, enter 10m or 600s.
The default is 0s, meaning that there is no power off delay.
6. Click Apply to save the configuration and apply the change.
The Apply button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
TX54 User Guide