Set Port Inlinepower - Enterasys G3G170-24 Cli Reference Manual

G-series
Hide thumbs Also See for G3G170-24:
Table of Contents

Advertisement

set port inlinepower

Mode
Switch command, read‐only.
Example
This example shows how to display PoE information for port 
administrative state, PoE priority and class have not been changed from default values:
G3(su)->show port inlinepower ge.2.1
Port
----
ge.2.1
set port inlinepower
Use this command to configure PoE parameters on one or more ports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
port‐string
admin off | auto
priority critical | 
high | low
type type
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to enable PoE on port 
G3(su)->set port inlinepower ge.3.1 admin auto priority critical
2-34 Basic Configuration
Type
Admin
Oper
----
-----
----
wireless
auto
searching
Specifies the port(s) on which to configure PoE.
Sets the PoE administrative state to off (disabled) or auto (on).
Sets the port(s) priority for the PoE allocation algorithm to critical 
(highest), high or low.
Specifies a string describing the type of device connected to a port.
ge.2.1
. In this case, the port's 
Priority
Class
--------
-----
low
0
ge
.3.1 with critical priority:
Power(W)
--------
15.4

Advertisement

Table of Contents
loading

Table of Contents