Configuring System Power and Power over Ethernet (PoE)

Parameters
featureID feature
Defaults
None.
Mode
Switch command, read‐write.
Example
    
This example shows how to clear the Advanced Routing licensed feature:
G3(rw)->clear license featureId g3advrouter
Configuring System Power and Power over Ethernet (PoE)
Some commands in this section apply only to PoE-equipped G-Series devices. Consult the Installation Guide
shipped with your product to determine if it is PoE-equipped.

Purpose

To review and set system power and PoE parameters, including the power available to the system, 
the usage threshold for each module, whether or not SNMP trap messages will be sent when 
power status changes, and per‐port PoE settings.

Commands

The commands used to review and set system power parameters are listed below.
For information about...

set system power

show inlinepower
set inlinepower threshold
set inlinepower trap
show port inlinepower
set port inlinepower
set system power
Use this command to set the status of power redundancy on the system
power supplies are installed, the G3 is set to operate in redundant mode.
Syntax
set system power {redundant | non-redundant}
2-30 Basic Configuration