clear spantree lpwindow

Use this command to reset the Loop Protect event window to the default value of 180 seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to reset the Loop Protect event window to the default of 180 seconds:
G3(rw)->clear spantree lpwindow

set spantree lptrapenable

Use this command to enable or disable Loop Protect event notification.
Syntax
set spantree lptrapenable {enable | disable}
Parameters
enable | disable
Defaults
None. 
Mode
Switch command, read‐write.
Usage
Loop Protect traps are sent when a Loop Protect event occurs, that is, when a port goes to listening 
due to not receiving BPDUs. The trap indicates port, SID and loop protection status. 
Example
This example shows how to enable sending of Loop Protect traps:
G3(rw)->set spantree lptrapenable enable
Enables or disables the sending of Loop Protect traps. Default is 
disabled.