Set Garp Timer - Enterasys G3G170-24 Cli Reference Manual

G-series
Hide thumbs Also See for G3G170-24:
Table of Contents

Advertisement

Example
This example shows how to clear GVRP status globally on the device:
G3(su)->clear gvrp

set garp timer

Use this command to adjust the values of the join, leave, and leaveall timers. 
Syntax
set garp timer {[join timer-value] [leave timer-value] [leaveall timer-value]}
port-string
Parameters
join timer‐value
leave timer‐value
leaveall timer‐
value
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Usage
The setting of these timers is critical and should only be changed by personnel familiar with the 
802.1Q standards documentation, which is not supplied with this device.
Examples
This example shows how to set the GARP join timer value to 100 centiseconds for all ports:
G3(su)->set garp timer join 100 *.*.*
This example shows how to set the leave timer value to 300 centiseconds for all ports:
G3(su)->set garp timer leave 300 *.*.*
This example shows how to set the leaveall timer value to 20000 centiseconds for all ports:
G3(su)->set garp timer leaveall 20000 *.*.*
Sets the GARP join timer in centiseconds (Refer to 802.1Q standard.)
Sets the GARP leave timer in centiseconds (Refer to 802.1Q standard.)
Sets the GARP leaveall timer in centiseconds (Refer to 802.1Q standard.)
Specifies the port(s) on which to configure GARP timer settings. For a 
detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 4‐1.
set garp timer
Enterasys G-Series CLI Reference 7-23

Advertisement

Table of Contents
loading