ABB IRB 6640 Product Manual page 241

Hide thumbs Also See for IRB 6640:
Table of Contents

Advertisement

3HAC026876-001 Revision: F
4.3.5. Replacement of cable harness, axes 1-4 IRB 6640ID
Action
5. Disconnect connectors R1.MP and R1.SMB.
6. Pull the cable and connectors up through the cable
guide in the center of the frame.
7. Disconnect all connectors at motors 1 and 2.
8. Open the SMB cover carefully.
The cable between the battery and the SMB-unit may
stay connected, in order to avoid an update of the
revolution counter. Be careful not to let the weight of
the cover strain the cable!
In order to remove the cover completely, the
connector R1.G must be disconnected! This causes
a necessary updating of the revolution counter!
9. Disconnect connectors R2.SMB, R1.SMB1-3,
R1.SMB4-6 from the SMB unit.
Disconnect X8, X9 and X10 from the brake release
unit.
4 Repair
Continued
Note
Attachment points are shown in
the figure
Location of cable
harness on page
237.
Specified and shown in the figure
Location of cable harness on
page
237!
0700000104
Continues on next page