ERROR CODES
The User Interface displays two error messages when the firmware
detects that an item is bad or not functioning. There are only 3 error
codes.
Error Code
Description
E450
Die type/code invalid
E451
Die encryption error
E452
Incompatible die
ERROR E451
DIE ENCRYPTION ERROR
The top row of text displays the fault error message number the bottom
row displays the description.
NOTE: If there is an ERROR message when downloading firmware
(either RM_XX_XX.BIN or RC_XX_XX.BIN file), the firmware should be
downloaded again.
GBC StreamPunch Ultra/Ultra MP
ERROR E450 DIE TYPE/CODE INVALID
This means that the die type is incorrectly set in the dieset.
1. Open the Front Door.
2. Remove the Die Set (see StreamPunch Ultra/Ultra MP/Ultra MP User
Manual).
3. Check that the Die Set is the correct Die Set for the Punch.
The Die Set is the correct die Set for the Punch.
Yes- Go to Step 4
4. Slowly re-insert the die set into the machine and close the front door.
This clears the fault.
Yes- Resume normal operation
No- Replace the Die Set and escalate to next level.
11-05-2018
2-11
No- Replace the Die Set
RTPS