ARP 2.10
Inner Exit Panel Replacement
PARTS LIST ON PL 2.1
Use this procedure to remove and install the Inner Exit Panel.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do GP 6.3 Undock the Punch to separate the Punch from the
downstream devices.
3. Do ARP 1.6 to remove the Rear Cover.
4. Do ARP 1.18 Downstream Docking plate removal
5. Do ARP 2.9 to remove the Lower Exit Panel.
6. Remove (2) screws from the front frame and (2) screws from the rear
frame that hold the Inner Exit Panel.
Adjustments/Repairs
7. Remove the Inner Exit Panel.
Installation Procedure
1. Place the Inner Exit Panel in position.
2. Tighten the (2) screws in the front frame and (2) screws in the rear
frame that hold the Inner Exit Panel.
3. Do ARP 2.9 to install the Lower Exit Panel.
4. Do ARP 1.18 to install Downstream docking plate
5. Do ARP 1.6 to install the Rear Cover.
6. Do GP 6.4 to dock the Punch to the downstream devices.
7. Connect the Power cord.
GBC StreamPunch Ultra/Ultra MP