GBC StreamPunch Ultra Service Manual page 43

Table of Contents

Advertisement

RTP 2.4
Jam Type D
Do the following if the lead edge of the first jammed sheet is past N6 and
N7 but its trail edge is before or just past N6/N7
1. Check to see if there is any obstruction in the paper path.
This clears the fault
Yes- Return to normal operation; No- Go to Step 2
2. Do RTP 3.1 to check Sensors S3, S4, S5, S22, S23, S24, and S25.
This clears the fault
Yes- Return to normal operation; No- Go to Step 3
3. Do RTP 3.2 to check Sensors S6, S7, S8, S9, S10, S11, S12, S13,
S14, S15, S16, S17, and S22.
This clears the fault
Yes- Return to normal operation; No- Go to Step 4
4. Do RTP 3.3 to check Sensor S28.
This clears the fault
Yes- Return to normal operation; No- Go to Step 5
5. Do RTP 4.3 to check Solenoids SOL3 to SOL8.
This clears the fault
Yes- Return to normal operation; No- Go to Step 6
6. Do RTP 5.1 to check Motors M1, M2, M3, M4, M5, M6 and M7.
This clears the fault
Yes- Return to normal operation; No- Go to Step 7
7. Do RTP 2.8 Checking Obstruction in Paper Path - Area 4 Punch
Module.
This clears the fault
Yes- Return to normal operation; No- Go to Step 8
8. Do GP 6.15 Drive Roller and Steering Drive Roller Inspection and
Cleaning, to Inspect and Clean Steering Drive Rollers
GBC StreamPunch Ultra/Ultra MP
This clears the fault
Yes- Return to normal operation; No- Go to Step 9
9. Do GP 6.14.2 Steering Idler Roller and Springs Inspection and
Cleaning.
This clears the fault
Yes- Return to normal operation; No- Go to Step 10
10. Inspect Punch Clutch Anti-Rotation Screw (M6 socket head screw) of
the Punch clutch. If it is loose, tighten it. See ARP 3.7 for details.
This clears the fault
Yes- Return to normal operation; No- Go to Step 11
11. Check the (2x) Cone Point Set Screws of the Punch Clutch. Tighten if
loose, Replace with new ones if missing. See ARP 3.7 for details.
This clears the fault
Yes- Return to normal operation; No- Go to Step 12
12. Do GP 6.23 Alignment Carriage Rails Cleaning.
This clears the fault
Yes- Return to normal operation; No- Go to Step 13
13. Inspect the ground strap in the Alignment Carriage Sub Assembly
(PL 4.3). If continuity is missing, fasten it with the appropriate screw. If
it is cut/damaged, replace the ground strap (PL 4.4).
This clears the fault
Yes- Return to normal operation; No- Go to Step 14
14. Check if the machine is docked properly- GP 6.4
This clears the fault
Yes- Return to normal operation; No- Go to Step 15
15. Inspect the Lower Exit Panel's magnetic latch, See ADJ 1.7 Idler
Panel Magnetic Latches Adjustment.
If the fault still exists, escalate to next level.