Sensor Checks; Rtp 3.1; Check Sensors S1, S2, S3, S4, S5, S22, S23, S24 - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

3 SENSOR CHECKS

RTP 3.1

Check Sensors S1, S2, S3, S4, S5, S22, S23, S24,

S25, S26
Use this RTP to check sensors S1, S2, S3, S4, S5, S22, S23, S24, S25,
S26.
1. Ensure that the front door is properly closed. Interrupted interlock
connection can trigger sensor paper jam codes.
2. Do GP 6.2.4 SENSORS Procedure. Check to make sure all sensors
should show "0" on the LCD when uncovered and "1" when covered.
If any sensor shows "1" when uncovered, clean that sensor. Also
check is there us any obstacle in the sensor window.
Sensors S1, S25, and S26 are on the Upper Bypass Panel (PL 3.5).
Sensors S2, S3, and S4 are on the Entrance Idler Panel (PL 3.2).
GBC StreamPunch Ultra/Ultra MP
Sensor S5 is on the Acceleration Roller Idler (PL 3.3)
S25
S26
S1
All sensors show "0" when uncovered and "1" when covered
Yes- Return to the RTP that directed you here.
S2
No- Go to Step 2
S3
S4
11-05-2018
2-33
S5
S24
S23
S22