GBC StreamPunch Ultra Service Manual page 33

Table of Contents

Advertisement

1 POWER FAULTS
RTP 1.1
No AC Power
Use this RTP when there is no AC power to the StreamPunch Ultra/Ultra
MP. The Operator Panel does not illuminate and the StreamPunch
Ultra/Ultra MP does not operate.
1. Check that the Power Cord is attached to the AC Filter on the rear of
the machine.
Power Cord is attached to AC Filter.
Yes-
Go to Step 2
No-
2. Check that the Power Cord is properly plugged into the wall.
Power Cord is plugged into the wall.
Yes-
Go to Step 3
No-
3. Disconnect the Power Cord from the power source and check for
input voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at the power
receptacle.
AC power is present at the recepticle.
Yes-
Go to Step 4
No-
If there is no power at the outlet, ask the customer to call an
electrician to restore the AC power.
4. Reconnect the power cord to StreamPunch Ultra/Ultra MP.
5. Check that Ground Wire 7715525 is connected to the ground and to
the AC Filter.
Ground Wire 7715525 is connected.
Yes-
Go to Step 6
No-
6. Check that Cable 7715598 is connected at the AC filter.
Cable 7715598 is connected at the AC filter.
Yes-
Go to Step 7
No-
GBC StreamPunch Ultra/Ultra MP
Attach the Power Cord.
Plug in the Power Cord.
Connect Ground Wire 7715525.
Connect Cable 7715598.
7. Check that Cable 7715598 is connected to the Communication board
at Pin J14.
Cable 7715598 is connected to the Communication board.
Yes-
Go to Step 8
No-
Connect Cable 7715598 to the ELCB.
8. Check the Fuse on the Communications Board.
Fuse is okay
Yes- Go to Step 9
9. Check that Wire 7715494 is connected to Pin J15 on the
Communications Board.
Wire 7715494 is connected to Pin J15 on the Communications
Board.
Yes-
Go to Step 10
No-
Connect Wire 7715494 to Pin J15 on the Communications
Board.
10. Check that Wire 7715494 is connected to Pin J4 on the Control
Board.
Wire 7715494 is connected to Pin J4 on the Control Board.
Yes-
Go to Step 11
No-
Connect Wire 7715494 to Pin J4 on the Control Board.
11. Check for input voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at
the AC Filter.
There is AC power at the AC Filter.
Yes-
Go to Step 12
No-
Replace the AC power cord to the AC Filter (PL 7.1).
12. Check for input voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) – on
Cable 7715598 at the AC Filter (BRN & BLU wires).
There is AC power on Cable 7715598 at the AC Filter.
Yes-
Go Step 13
11-05-2018
2-16
No-
Replace the Fuse (PL 6.1).
No-
Replace AC FILTER (PL 6.1).
RTPS