ARP 2.11
Upper Bypass Panel Replacement
PARTS LIST ON PL 2.1, PL 3.5
Use this procedure to remove and install the Upper Bypass Panel.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do GP 6.3 to undock the Punch from the upstream and downstream
equipment.
3. Do ARP 1.6 Rear Cover Replacement to remove the Rear Cover.
4. Unplug the Sensors from the Upper Bypass Panel and release the
sensor cables from the cable clamps.
5. Remove the screw and nut for the ground strap.
GBC StreamPunch Ultra/Ultra MP
6. Remove (2) E-clips from the hinge shaft and remove the shaft.
7. Remove (2) Idler panel magnetic latches from the Upper bypass
assembly by unscrewing (4) screws.
02-03-2017
4-39