RTP 2.6
Jam Type F
Do the following if there is any obstruction in the paper path in the bypass
section.
1. Check is there is any obstruction in the paper path in the bypass
section.
Do RTP 2.1 Jam Type A.
This clears the fault
Yes- Return to normal operation; No- Go to Step 2
2. Do RTP 3.1 Check Sensors S1, S2, S3, S4, S5, S22, S23, S24, S25,
S26.
This clears the fault
Yes- Return to normal operation; No- Go to Step 3
3. Do RTP 5.1 Checking Stepper Motors to check Bypass Motor M8 (PL
2.6).
This clears the fault
Yes- Return to normal operation; No- Go to Step 4
4. Check the Diverter mechanism, do RTP 4.1.
This clears the fault
Yes- Return to normal operation; No- Go to Step 5
5. Check the nip force of rollers N1, N11, N12, N13 and N14. This can
be done by:
Do GP 6.14 Idler Roller Inspection and Cleaning to inspect the
idler roller springs for these rollers
Do GP 6.15 Drive Roller Inspection and Cleaning to check the
Drive Roller condition. Clean if necessary.
Check the Paper path drive panel positions- see ADJ 1.8, and
perform adjustments if necessary.
Check the Exit Idler Panel position- see ADJ #1.7 Idler panel
Magnetic Latches adjustments, perform adjustment is necessary.
This clears the fault
Yes- Return to normal operation; No- Escalate to second level