Gp 6.2.7 Motors Check - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

GP 6.2.7
MOTORS Check
Do the following to test any of the Stepper Motors.
The Motors feature allows you to test the operation of each of the 8
stepper motors to the StreamPunch Ultra/Ultra MP.
Do the following to check the Motors.
1. At the top level screen,
READY
SINGLE PUNCH
Press and hold both the Up Arrow button and the Down Arrow button
for 5 seconds.
Then while still holding down the Up Arrow button and the Down
Arrow button, press the Enter button.
The Service User Interface screen will appear.
PAPER SIZE
MAX BYPASS
2. Press the down arrow so the return symbol is next to the words
SOLENOIDS.
SOLENOIDS
MOTORS
General Procedures and Information
*
*
3. Press the ENTER button when the return symbol is next to the word
Motors to display the display the first MOTORS screen.
M1 M2 M3 M4
M6 M7 M8
4. To check the Stepper Motors:
NOTE: Door needs to be closed to do this.
Press the down arrow to scroll through the motor options.
The selected motor will flash on and off.
Press the Enter button to turn the selected motor on.
You should hear the motor running
(a low whine for Motors M1, M2, M6, M7< & M8)
(a soft whine for Motors M3, & M4),
Press the Enter button again to turn the selected motor off
Repeat as needed to check the other Stepper Motors.
5. When you finish checking the Motors:
Press the up or down arrow to highlight the BACK option.
Press the ENTER button to display the Service mode menu
Press up or down to display the Previous Menu and Exit Options.
GBC StreamPunch Ultra/Ultra MP
11-05-2018
6-32
*
BACK

Hide quick links: