GP 6.12 Die Guide Cleaning

Do the following to clean the Die Guide every 500K cycles.
1. Remove the Die Set and clean the guide [1] with a vacuum cleaner.
GBC StreamPunch Ultra/Ultra MP

GP 6.13 Door Latch Inspection

Inspect the Door Latch every 1000K cycles.
The door latch must hold the door closed and ensure that the switch
activation tab is depressing the door switch [1]. The switch tab [2] should
press the switch button just so that it is close to bottom.
1. Ensure latch holds door closed.
2. Ensure switch is activated when the door is closed.
3. To adjust the door latch, see ADJ 1.1