ARP 2.2 Inner Entrance Panel Replacement

PARTS LIST ON PL 2.1
Use this procedure to remove and install the Inner Entrance Panel.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do GP 6.3 Undock the Punch to separate the Punch from the
upstream and downstream devices.
3. Do ARP 1.6 to remove the Rear Cover.
4. Do ARP 1.17 to remove the Lower Entrance Panel.
5. Remove the screws (2) from the front frame and the Screws (2) from
the rear frame that are used to mount The Lower Entrance Panel.
GBC StreamPunch Ultra/Ultra MP
6. Remove the Inner Entrance Panel.
Installation Procedure
1. Place the Inner Entrance Panel in position.
Ttighten the screws (2) in the front frame and the Screws (2) in the
rear frame that are used to mount The Lower Entrance Panel.
2. Do ARP 1.17 to install the Lower Entrance Panel.
3. Do ARP 1.6 to install the Rear Cover.
4. Do GP 6.4 Dock the Punch to connect the Punch to the upstream and
downstream devices.
5. Connect the Power Cord.