Motors
The Motors feature allows you to test the operation of each of the 9
motors to the StreamPunch Ultra/Ultra MP.
Press the Up Arrow button and Down Arrow buttons to scroll through the
list of motors.
Function Tests
The Function Tests feature allows you to run the Cycle Punch and Aligner
Test routines.
Press the Up Arrow button and Down Arrow buttons to highlight the
desired test.
Press the Enter button to run the test. Press the Enter button again to
stop the test.
The Cycle Punch Test starts the Punch Motor, waits for 2 seconds, the
triggers the Punch at 1 punch per second for 5 cycles.
The Aligner Test moves the home Aligner CW 10mm, back to home,
CCW 10mm, then back to home. It repeats this cycle 5 times.
The Fan Test starts the Exhaust Fan at the rear of the Punch..
GBC StreamPunch Ultra/Ultra MP
Skew Offsets
The Skew Offsets feature allows you to setup the skew offsets to
straighten and offset punch depth. The options are:
BG LEFT
BG RIGHT
BG DP L LEFT
BG DP L RIGHT
BG DP XL LEFT
BG DP XL RIGHT
Align Offsets
The Align Offsets feature allows you to setup the align offsets to
straighten and offset punch depth.
Log
The LOG file download option will save the information about the last 50
punched sheets to a USB flash drive.
Die Cycles
This displays the number of cycles punched with the dieset that is
currently installed in the machine.
Firmware Update
The Firmware Update feature allows you to update the firmware for the
Punch.