ARP 2.15
Idler Roller Replacement
PARTS LIST ON PL 3.2, PL 3.3, PL 3.4, PL 3.5
Use this procedure to remove and install the Idler Rollers or the Retaining
Springs in these assemblies:
Entrance Idler Panel.
Acceleration Roller Idler Assy.
Exit Idler Panel.
Bypass Panel
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do the following to access the Idler Rollers.
For the Idler Rollers in the Entrance Idler Panel, Acceleration
Roller panel, Exit Idler panel, undock the punch from upstream
and downstream devices, GP 6.3
For the Idler Rollers in the Bypass Panel, Open the Front Door.
Adjustments/Repairs
3. Lift the Extension Spring (2) up off the Bearing Housing (2) at each
end of the Idler Roller Shaft.
Idler Roller Shaft
Idler Roller
Retaining Spring
4. Remove the Idler Roller with the Bearing Housings (2) from the
Bushing Forks.
5. Remove the Bearing Housing (2) at each end of the Idler Roller Shaft.
(Cont.)
GBC StreamPunch Ultra/Ultra MP
02-03-2017
4-44
Bearing Housing