Other Faults; Rtp 6.1 Die Set Will Not Slide In Or Out Easily; Rtp 6.2 Punch Overheats - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

6 OTHER FAULTS

RTP 6.1
Die Set Will Not Slide In or Out Easily
Use this RTP when the Die Set will not slide in or out using a moderate
pull.
1. Do GP 6.27 Die Lock Mechanism and Die Rail Springs Inspection.
This clears the fault
Yes- Return to normal operation; No- Go to Step 2
2. Check if the Punch Cam needs to be indexed. Do ADJ 1.5 Punch
Clutch Indexing and perform the adjustment if necessary.
This clears the fault
Yes- Return to normal operation; No- Escalate to second level
GBC StreamPunch Ultra/Ultra MP
RTP 6.2
Punch Overheats
Use this RTP if the Punch Overheats.
Note: To prevent excessive heat build-up, the maximum recommended
monthly punch volume should not exceed 400,000. In addition, no more
than 2 sheets of 300gsm per 5 sheets of 75 gsm.
1. Check that the Exhaust Fan operates when power is on. Do GP 6.2.8
Function Tests- Fan Test.
The exhaust fan operates
Yes-
Go to Section 3.13 Punch specifications and make sure the
machine is used per the Duty cycle specifications. Resume
normal operation if specifications are met.
No-
Go to step 2.
2. Check for obstructions at the vents in the Rear Cover.
There are no obstructions at the vents in the Rear cover
Yes-
Go to Step 3
No-
Clear the obstruction and resume normal operation.
3. Check for 24 VDC on Wire 7715267 at the Exhaust Fan.
There is 24 VDC
Yes-
Replace the Exhause fan (PL #)
No-
Go to Step 4
4. Check for 24 VDC on Wire 7715267 at Connector J20 on the Control
Board.
There is 24 VDC
Yes-
Replace Wire 7715267.
No-
Do RTP 1.2 No DC power.
11-05-2018