ARP 2.19
Bearing Housing Replacement
PARTS LIST ON PL 3.2, PL 3.3, PL 3.4, PL 3.5
Use this procedure to remove and install the Bearing Housings for the
Idler Rollers in these assemblies:
Entrance Idler Panel.
Acceleration Roller Idler Assy.
Exit Idler Panel.
Bypass Panel
1. Do ARP 2.15 to remove the Idler Roller with the Bearing Housings (2)
from the Bushing Forks.
Idler Roller
2. Remove the old Bearing Housings (2) from the ends of the Shaft.
3. Place the new Bearing Housings (2) on the ends of the Shaft with the
flange of the Bearing facing in toward the Idler Roller.
Bearing Housing
4. Do ARP 2.15 to install the Idler Roller.
GBC StreamPunch Ultra/Ultra MP
Bearing Housing
Bearing flange
ARP 2.20
Accel Idler Latch Handle Replacement
PARTS LIST ON PL 2.2
Use this procedure to remove and install the Accel Idler Latch Handle or
the Accel Idler Shaft.
Removal Procedure
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Open the Front Door.
3. Remove (2) screws from the Accel Idler Latch Handle.
02-03-2017
4-49
WARNING
Adjustments/Repairs

Hide quick links: