Arp 2.29 Motor Driver (Stepper Board) Replacement - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

ARP 2.29
Motor Driver (Stepper Board) Replacement
PARTS LIST ON PL 2.6
Use this procedure to remove and install a Motor Driver (Stepper Board) -
DRV M1, DRV M2, DRV M3, DRV M4, DRV M5, DRV M6, DRV M7, or
DRV M8.
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do ARP 1.6 to remove the Rear Cover.
3. Locate the appropriate Motor Driver (see PL 2.6).
4. Disconnect the Connectors (3)
5. Remove the M4 Screws (2) and the Driver and Bracket Assembly.
6. Disconnect the Cables from the Motor Driver Board.
7. Set the Dip switches (6) on the new Motor Driver in accordance with
the table below.
Adjustments/Repairs
Connectors (3)
Screws (2)
Dip Switches (5)
Connectors (3)
M1 Motor Driver
M2 Motor Driver
1
Off
1
2
On
2
3
Off
3
4
On
4
5
Off
5
M4 Motor Driver
1
Off
2
Off
3
On
4
On
5
On
M6 Motor Driver
M7 Motor Driver
1
Off
1
2
On
2
3
Off
3
4
On
4
5
Off
5
8. Place the Driver and Bracket Assembly in position and tighten the M4
Screws (2).
9. Connect the Connectors (3).
10. Do ARP 1.6 to install the Rear Cover.
11. Connect the Power Cord.
GBC StreamPunch Ultra/Ultra MP
02-03-2017
4-74
M3 Motor Drive
Off
1
Off
On
2
Off
Off
3
On
On
4
Off
Off
5
On
M5 Motor Drive
1
Off
2
Off
3
On
4
Off
5
Off
M8 Motor Driver
Off
1
Off
On
2
On
Off
3
Off
On
4
Off
Off
5
Off