Check Die
The CHECK DIE message indicates that the Die Set is either missing or
not fully installed.
1. Open the Front Door.
2. Unlock the Dieset, and remove the Dieset (see StreamPunch
Ultra/Ultra MP/Ultra MP User Manual).
3. Re-insert the Dieset and lock the lock it in place.
This clears the fault code.
Yes- Normal operation;
4. Do ARP 1.6 to remove the Rear Cover, and check if the Dieset
Recognition Reader Board Cable (7715495) is connected properly at
both ends (see PL 6.4 or Section 7 wiring). Note that the connector
has 4 pins, and it should be properly inserted.
This clears the fault code.
Yes- Normal operation;
5. Clean the Dieset Recognition Board in the Die and the Die set
Recognition Reader Board in the machine.
This clears the fault code.
Yes- Normal operation;
GBC StreamPunch Ultra/Ultra MP
No- Go to step 4.
No- Go to step 5.
No- Go to step 6
6. Check if the Dieset Recognition Reader Board Spring Clips contact
the Dieset Recognition Board in the Dieset.
If Spring Clips are broken, Replace Dieset Recognition Reader
Board. If the springs clips do not contact the Dieset Recognition
Board, do ADJ 1.6 Dieset Recognition Board Adjustment.
This clears the fault code.
Yes- Normal operation;
7. If there is another Dieset, check if that Dieset shows the same
message.
Dieset shows the same message.
Yes- If the error is still present with all the diesets, do GP 6.2.12
FIRMWARE UPGRADE Procedure to reflash the firmware.
No- If the issue is with just one Dieset, then escalate to next level
This clears the fault code.
Yes- Normal operation;
8. Replace the Dieset Recognition Cable #7715495 (Section 7 Wiring).
This clears the fault code.
Yes- Normal operation;
11-05-2018
2-6
No- Go to step 7.
No- Go to Step 8.
No- Go to step 9.