ARP 3.27
Die Set Recognition Replacement
PARTS LIST ON PL 4.9
Use this procedure to remove and install the Die Set Recognition
Assembly.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do ARP 1.6 to remove the Rear Cover.
3. Disconnect the Die Set Recognition Cable.
(Cont.)
Adjustments/Repairs
Die Set
Recognition Cable
4. Remove the Screws (2) and the Die Set Recognition Board Mount
Bracket.
Die Set Recognition
Bracket
5. Place the new Die Set Recognition Board Mount Bracket in position
and tighten the Screws (2).
6. Connect the Die Set Recognition Cable.
7. Do ARP 1.6 to install the Rear Cover.
8. Do ADJ 1.6 Die Set Recognition board adjustment procedure.
9. Connect the Power Cord.