ARP 1.10
Door Latch Replacement
PARTS LIST ON PL 1.2
Use this procedure to remove and install the Door Latch Assembly.
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
Do the following to ensure the door latch holds the door closed and that
the activating bracket tab [1] depresses the door switch[2]. The tab should
press the switch button just so that it is close to bottoming out.
1. Disconnect the Power Cord.
2. Open the Front Door.
3. Remove the two screws [1] on the Door Latch.
4. Remove Screws (2) from the Interlock Box.
GBC StreamPunch Ultra/Ultra MP
Screw (2)
02-03-2017
5. Remove the old Latch and put the new Latch in position.
6. Do ADJ 1.1 to adjust the Door Latch.
7. Tighten the Screws (4).
8. Close the Front Door.
9. Connect the Power Cord.
10. Test the Door Latch operation.
4-11