ARP 1.7 Upstream Rear Side Cover Replacement
PARTS LIST ON PL 1.2
Use this procedure to remove and install the Upstream Rear Side Cover.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do GP 6.3 to undock the Punch from the upstream and downstream
equipment.
3. Do ARP 1.6 to remove the Rear Cover.
4. Remove the Screws (5) from the Upstream Rear Side cover
5. Remove the Upstream Rear Side Cover.
Installation Procedure
1. Place the Upstream Rear Side Cover in position.
2. Tighten the Screws (5) holding the Upstream Rear Side Cover.
3. Insert and tighten the Screw at the left side of the Exhaust Fan
Bracket Assembly.
4. Do ARP 1.6 to install the Rear Cover.
5. Do GP 6.4 to dock the Punch to the upstream and downstream
equipment.
6. Connect the Power Cord.
Adjustments/Repairs
GBC StreamPunch Ultra/Ultra MP
02-03-2017